文档

​
​

Development

User Acquisition

Monetization

工业

Vivox Unreal SDK

Vivox Unreal SDK

此页面不支持所选语言。
Vivox
​
​
Vivox Unreal SDK
  • Overview
  • Get started
  • Release notes
  • Developer guide
    • Set up your project
    • Unity Authentication Service in Unreal
    • Create voice and text channels
    • Messaging
    • Audio management
    • Muting
    • In-game moderation
    • Android app development
    • iOS app development
    • Server-side recording
    • Speech-to-text audio transcription
    • Text-to-speech
    • Real-time recording
    • Transmission
    • Troubleshooting
      • Voice activity detection
        • Parameter specifics
        • VAD adjustments
      • Vivox SDK error codes
  • Tutorials
  • Reference
  1. Vivox Unreal SDK documentation
  2. Troubleshooting

Parameter specifics

Review voice activity detection parameter specifications.
阅读时间1 分钟
最后更新于 8 个月前

vad_hangover

The hangover time is the time (in milliseconds) it takes for the VAD to switch back from speech mode to silence after the last speech frame is detected. The default value is 2000.

vad_sensitivity

The sensitivity is a dimensionless value between 0 and 100 that indicates the sensitivity of the VAD. Increasing this value corresponds to decreasing the sensitivity of the VAD (0 is the most sensitive, and 100 is the least sensitive). Higher values of sensitivity require louder audio to trigger the VAD. The default value is 43.
Applications that use the default VAD and expose the vad_sensitivity as a slider should limit the possible settings between zero (transmit all mic activity) and 70 (very selective).

vad_noise_floor

The noise floor is a dimensionless value between 0 and 20000 that controls how the VAD separates speech from background noise. Lower values assume the user is in a quieter environment where the audio is only speech. Higher values assume a noisy background environment. The default value is 576.
注意
Changes to the VAD noise floor settings do not affect currently joined channels. If the ability to change VAD settings is available to the end-user, indicate that noise floor changes only take effect in the next voice session or only allow changing the noise floor channel when the client is not in-channel.

Copyright © 2026 Unity Technologies
法律信息隐私政策CookiesDocumentation Terms of Use请勿出售或分享我的个人信息您的隐私选择(Cookie 设置)

“Unity”、Unity 徽标及其他 Unity 商标是 Unity Technologies 或其附属公司在美国和其他地方的商标或注册商标(此处查看更多信息)。其他名称或品牌是其各自所有者的商标。

为方便起见,一些页面是机器翻译的,可能包含不准确的内容。如有信息不一致的情况,以英文版本为准。

  • 在本页上
    • vad_hangover

    • vad_sensitivity

    • vad_noise_floor


报告此页面的问题